80Amp Auto relay HRA5
Product Features
High Current rating
The HRA5 relay is rated to switch loads up to 80A, making it ideal for applications requiring substantial current, including automotive motors, high-intensity lighting, and other heavy electrical devices.Typically designed for use with 12V or 24V DC systems, aligning with the standard voltage levels in most automotive applications. This ensures compatibility across various vehicle models.


HRA5 Common Applications
Automotive Lighting: Used to control high-beam headlights, fog lights, or other heavy-duty automotive lighting systems.
Electric Motors: Suitable for starting and operating electric windows, sunroofs, fans, and power seats.
Accessory Power: Commonly deployed in aftermarket applications to control additional electrical accessories fitted to vehicles.
Winches and Trailers: Used in controlling electric winches or towing equipment that demands high current.
Efficiency ,Reliability and Safety
Allows for efficient control of high-power devices without the need for heavy-duty switch gear, reducing overall weight and complexity in automotive design.
Robust construction and protective features enhance the reliability of high-power applications, leading to fewer failures and lower maintenance costs.
Proper usage of relays like the HRA5 can help protect the vehicle’s wiring harness by relieving electrical stress, reducing the risk of overheating and potential fire hazards.

Wire length can be customized
Odering Information
① Part No. | ||||||
HRA5 - S - DC12V - A - L - R | ② S :Plastic sealed Nil:Dust Cover | |||||
③ Coil Voltage : | ||||||
① ② ③ ④ ⑤ ⑥ | DC 6, 12, 24V | |||||
④ Contact form: | ||||||
A: 1N/O C: 1C/O B : 1N/C | A : 1 Form A | |||||
⑤ Version | ||||||
Nil : Without Bracket | ||||||
L : Plastic bracket | ||||||
T : Metal bracket | ||||||
P: PCB terminal | ||||||
⑥Parallel coil components R: With Resistor 12V-680Ω,24V2700Ω D: With Diode Nil :Standard |
Specification:
Contact | Characteristics | ||||||
Contact Form 1 Form A | Insulation resistance | Min 100MΩ(500VDC) | |||||
Contact Material | Ag Alloy | Dielectric Strength | Between contact 550VAC 1min | ||||
Contact Resistance | 25 mΩ(24VDC 1A) | Between coil &contact 550VAC 1min | |||||
Contact Rating(Resistance Load) | Operate time ≤ 10ms | ||||||
NO: 80A /14VDC NC :40A /28VDC | Release time ≤ 10ms | ||||||
Inductive: make 150A/14VDC,break 50A/14VDC | Shock Resistance | Endurance | 100 m/s2 | ||||
Lamp:Surge 200A/14VDC ,40A/14VDC | Damage | 1000 m/s2 | |||||
Max Switching Voltage | 75VDC | Vibration Resistance 10-55 HZ 1.5mm DA | |||||
Max Switching Current | 80A | Humidity 35%-95% RH | |||||
Max Switching Power | Ambient Temperature -40 ℃ to 125℃ | ||||||
Electrical Life | 100,000 ops | Weigt Approx. 37.0g | |||||
Mechanical Life | 1,000,000 ops | Noted :the data are initial value |
Coil Data
Nominal Voltage VDC | Operate Voltage Max VDC | Release Voltage Min VDC | Max Voltage VDC | Coil Resistance Ω +/- 10% | ||||
12 | 7.8 | 1.2 | 20 | 90 | ||||
24 | 16.00 | 2.40 | 40.00 | 320 | ||||
12(R) | 7.80 | 1.20 | 20.00 | 90 | ||||
24(R) | 16.00 | 2.40 | 40.00 | 320 |
QC terminal


PCB terminal